Release Notes - NSBA IRM Evaluator NOTE: Cell callouts listed below may not necessarily align with current state of spreadsheet as rows and columns may have been added and subtracted in subsequent versions. Version 2.1 - December 2020 1 - Includes v1.7 Axial spreadsheet. This update corrects the fastener hole area calculation in the angles and other misc. improvements. 2 - Includes v1.9 Flexural spreadsheet. This update adds a feature to add fastener holes in the flange for box members with multiple flange plates, and other misc. improvements. 3 - See "Version Notes" within each spreadsheet for more information. Version 2.00 - June 26, 2020 1 - Initial release of NSBA IRM Evaluator for axial and flexural members. 2 - Includes v1.07 Flexural spreadsheet. 3 - Includes v1.06 Axial spreadsheet. This is an update to the earlier released version (v1.04) which includes spelling errors corrections, and improved cell function logic for total remaining fatigue life. calculation in faulted state, added FCP input override option and input clearing buttons. 4 - See "Version Notes" within each spreadsheet for more infomation on what's new.